• 概覽
  • 技術(shù)參數(shù)


Graco’s SoloTech 26 Hose pump design utilizes a single roller that compresses an engineered hose through a full 360 degrees of rotation. This innovative design means longer hose life when pumping caustic, abrasive or sensitive materials for metering or transfer.


功能


More flow per revolution than conventional designs

Inexpensive to maintain - no valves, seals or glands

Pumps are reversible and can be used to empty lines or clear blockages

Extended hose life - only one hose compression per revolution


SoloTech Peristaltic Pumps

Maximum Fluid Working Pressure

0.9 MPa, 9 bar

Motor Horsepower/Gear Ratio

See the identification tag on your gear motor.

Maximum Pump Speed

90 RPM

Environmental Temperature Range (Do not allow material to freeze in the pump.)

–10°C to 40°C

Maximum Flow

ST10

2.5 lpm

ST23

17.0 lpm

ST26

37.1 lpm

ST30

59.8 lpm

Fluid Capacity per Revolution

ST10

0.03 l

ST23

0.20 l

ST26

0.42 l

ST30

0.68 l

Flange Dimensions

ST10

Outer Diameter

90 mm

Bolt Circle

58–65 mm

Bolt Size

1/2 in.

ST23 and ST26

Outer Diameter

108 mm

Bolt Circle

75–80 mm

Bolt Size

1/2 in.

ST30

Outer Diameter

125 mm

Bolt Circle

85–90 mm

Bolt Size

1/2 in.

Hose Inner Diameter

ST10

10 mm

ST23

23 mm

ST26

26 mm

ST30

30 mm

Weight

ST10

25–29 kg

ST23

45–54 kg

ST26

86–98 kg

ST30

107–129 kg

Noise

Sound Pressure

Less than 70 dB(A)

Wetted Parts

Hose options

Natural Rubber, CSM, EPDM, NBR

Barbed fitting options

Stainless steel, PVDF, Hastelloy

Technical Specifications for the Graco Motor Control (All installations and wiring must comply with NEC and local electrical codes.)

DC Power Supply

Class 2 Power Supply only

Approvals

UL508C

Conformity

CE-Low Voltage (2006/95/EC), EMC (2004/108/EC), and RoHS (2011/65/EU) Directives

Ambient Temperature

–40°C – 40°C

Environment Rating

Type 4X, IP 66

Overtemperature Sensing Specifications (The drive is provided with a means to accept and act upon a signal from a thermal sensor in the motor. Motor overtemperature sensing is required to provide the motor overload protection.)

0–3.3 VDC, 1mA maximum

Weight

4.8 kg

Input Specifications

Input Line Voltage

120/240 VAC, line-to-line

Input Line Phasing

Single Phase

Input Line Frequency

50/60 Hz

Input Current per Phase

16A

Maximum Branch Circuit Protection Rating

20A, Inverse Time Circuit Breaker

Short Circuit Current Rating

5 kA

Output Specifications

Output Line Voltage

0–264 VAC

Output Line Phasing

Three Phase

Output Current (Current limit, set via the software, is provided as a secondary protection from motor overload.)

0–12A

Output Power

1.92 KW / 2.6 hp

Output Overload

200% for 0.2 seconds

?